NX-1700E Card Reader
7
DE-ACTIVATE ONE USER
ACTION
RESULT
& [BYPASS]
x x x x x x x x
Accesses De-activation mode
& [3-digit user number]
Example: X Y [ if 4-digit user code
or
W W X Y [ if 6-digit user codes
x x x x x x x x
If a valid user number is entered, LED1 on any enabled readers will
begin to flash.
Scan any card
x x x x x x x x
The card information for the user entered in the previous step will
be cleared, and LED1 will stop flashing. After about 30 seconds, all
the readers in the system will be updated.
DELETE / RESET ONE USER
ACTION
RESULT
& [EXIT]
x x x x x x x x
Accesses De-activation mode
& [3-digit user number]
Example: X Y [ if 4-digit user code
or
W W X Y [ if 6-digit user codes
x x x x x x x x
If a valid user number is entered, LED1 on any enabled readers will
begin to flash.
Scan any card
x x x x x x x x
The card information for the user entered in the previous step will
be cleared, and LED1 will stop flashing. After about 30 seconds, all
the readers in the system will be updated.
VII. PROGRAMMING LOCATIONS
SCAN METHODS: Legacy mode is default. Alternative mode is shown below in brackets { }.
Refer to Location 242 Segment 1 on page 8, and the Glossary on page 16 for explanation.
LOCATION 0 PROGRAMMING THE SCAN FUNCTIONS
(3 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card is scanned. More than one
function may be selected. If more than one function is selected, they will execute in order from function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [À] [6] function (refer to keypad
user manual).
Segment 1 Single Scan Function {Single Beep}
Program the functions that are performed when a card is scanned {one beep}.
LED1 - "On" to send Code Entry function to the control panel.
LED2 - "On" to activate the Armed Away mode.
LED3 - "On" to activate the Armed Stay mode.
LED4 - "On" to send the Disarm function to the control panel.
LED5 - "On" to send Auxiliary Function #1 to the control panel.
LED6 - "On" to send Auxiliary Function #2 to the control panel.
LED7 - "On" to broadcast an X-10 function (see Location 241 for programming).
LED8 - "On" to send a Request To Exit (RTE); and activate the onboard open collector output. (Default is “On”) Location
243, Segment 2 must be programmed with a valid zone number for the RTE to be sent.
If an individual keeps the
card, it can still be deleted.
ACTIVATING / DE-ACTIVATING / RESETTING USERS
If User Number 0 is entered, the desired function will be performed on the user associated with the card scanned.