15
LOCATION 130: ENABLING THE SWINGER SHUTDOWN
Location 130 is used to enable the burglary zone swinger shutdown. The number programmed in this location, will
determine the number of trips the Ranger 8600 will allow, before bypassing all burglary zones (1-8) which have
tripped during an arming cycle. The bypassed zones will not report trips to a central station, and the local siren or
bell will not sound for these zones. A zone trip will not be added to the number count until after the zone has tripped
more than once. A zone trip will only be added each time the siren cycle starts. If this location contains a "0", this
feature is disabled. A zone which has been bypassed by this feature will be reported if bypass reporting is enabled
in location 125. If "Immediate Restore By Zone" is enabled in location 137, multiple reports may be
transmitted during a siren cycle without adding to the trip count.
LOCATION 131: AUTOMATIC BYPASS / INSTANT ARMING
Location 131 is used to enable automatic "Instant Arming". Programming a "1" in this location will cause the control
to automatically enter the "Instant" mode and bypass interior follower zones if a fault is not detected on an entry/exit
zone during the exit delay. Programming a "3" in this location (Automatic Bypass), will cause the interior follower
zones to become bypassed if a fault is not detected on an entry/exit zone, yet will not change the status of the
entry/exit zone. If this location contains a "0", these features are disabled. Pressing the [r] key when the system is
armed, will cause the "Instant" light to toggle. When the "Instant" light is on, the entry/exit zone is instant; when off,
the entry/exit zone is delayed. The [r] key will toggle the "Instant" mode regardless of the programming data in this
location.
LOCATION 132: BUILT-IN SIREN DRIVER / 1 AMP VOLTAGE OUTPUT
The built-in siren driver has a steady sound (for Priority zone type), and a yelp sound (for Burglary and Panic).
Factory default is "0", enabling this feature. If the built-in siren driver is NOT to be used, take the following procedure.
First, remove the jumper marked voltage/siren on the PC board. Next, program a "1" in location 132. Finally, replace
the jumper in the voltage position. Terminals 21 & 22 will now output 1 Amp at 12VDC.
LOCATION 133: L.E.D. EXTINGUISH FEATURE
Keypad LEDs (excluding the A.C. LED) will be extinguished after 60 seconds of keypad inactivity, if a "1" is
programmed in location 133. The LEDs will become illuminated immediately upon a keypress or alarm condition.
LOCATION 134: ENTERING THE NUMBER OF DIAL ATTEMPTS
Location 134 is used to enter the number of dial attempts (1 to 15 attempts) the communicator will try for the
appropriate phone number(s) before ending the notification process. If this location contains an "8", the communicator
will make eight attempts to the first number, and then eight attempts to a second number, if a second number is
programmed as backup.
LOCATION 135: POWER UP CONDITION
If a "1" is programmed in location 135, the Ranger 8600 will power-up disarmed if there is a total power shutdown
and battery failure. If a "2" is programmed in this location, it will power up armed. If this location contains a "0", the
Ranger 8600 will power up in the condition it was in at power down. A watchdog circuit reset will cause the Ranger
8600 to reset to the selected condition.
LOCATION 136: POWER UP DELAY
If a "1" is programmed in location 136, the Ranger 8600 will not delay 60 seconds before accepting open or short
inputs from any zone. If a "0" is programmed, sensors on all zones are allowed 60 seconds to stabilize at power-up..
After 60 seconds, the Ranger will once again accept loop opens or shorts as an alarm condition. This 60 second
period will also be initiated after exiting the program mode, or a watchdog circuit reset condition.