GE Security g NetworXTM Series NX-6-EUR Control Panel Installation manual
GE Security g Guard codes (Sweden) User codes 16 and 17 can be considered as so called “guard codes”. In this case, user codes 16 and 17 ca
GE Security g CE DECLARATION NX-6-EUR Installation manual Page 100 23/12/04
GE Security g NX-6-EUR Installation manual Page 101 23/12/04 GE Security g NX-6-EUR Installation manual Page 101 23/12/04
GE Security g NX-6-EUR Installation manual Page 102 23/12/04
GE Security g NX-6-EUR Installation manual Page 103 23/12/04
www.gesecurity.com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT ©2004 © GE
GE Security g Local programming lockout This feature will disable programming of all locations, or for specified locations, from the keypa
GE Security g Siren blast for arming The NX-6 can be programmed to give a one-second siren blast when the panel is armed, at the end of the
GE Security g Zone activity monitor This feature will send a report to the central station when a particular zone does not change conditio
GE Security g PROGRAMMING THE NX-6 KEYPADS Programming the LED keypads This section describes how to program the address and partition for
GE Security g [*]-[9]-[4] SET KEYPAD NUMBER AND PARTITION 1. Enter [*]-[9]-[4]-[program code]- the “Service” LED and the “Instant” LED
GE Security g [*]-[5] CHANGING USER CODES 1. Enter [*]-[5]-[master code]- the “Ready” LED will flash. 2. Enter the 2 digit user
GE Security g NOTE: ANY MASTER ARM/DISARM CODE CAN ADD OR CHANGE A USER CODE IF THE MASTER CODE HAS ACCESS TO THE SAME PARTITIONS AS THE CO
GE Security g Programming the NX-148 LCD keypads This section describes how to program the address and partition for each keypad, and it al
GE Security g [*]-[9]-[3] SET KEYPAD OPTIONS 1. Enter [*]-[9]-[3] The LCD screen will prompt for a code. 2. Enter [program code] The L
GE Security g NX-6-EUR Installation manual Page 2 23/12/04
GE Security g Remark : In the menu “Select an option” 8 additional options can be selected. The options 5 until 8 are not used for the mo
GE Security g Keypad functions for the NX-148 LCD keypad The LCD keypads have a bilingual user’s interface. As a result, you can simply sel
GE Security g [*]-[9]-[0] READING THE EVENT LOG The NX-6 has a 512-event log which can be retrieved using a master code. This log contain
GE Security g [*]-[▲] VIEW ZONE STATUS 1. Enter [*]-[▲] The LCD screen will display the zone status. 2. Use the ‘up’ and ‘down’ scroll
GE Security g [*]-[6] ASSIGNING AUTHORITY LEVEL Note: You must be authorized to access the partition that you wish to add to, or remove
GE Security g [*]-[CHIME] ACTIVATING WALKTEST 1. Enter [*]-[CHIME] The LCD screen will prompt you for a “master code”. 2. Enter [master
GE Security g PROGRAMMING THE NX-6 CONTROL PANEL Programming the NX-6 control panel via the LED keypad ENTERING THE PROGRAM MODE To enter
GE Security g EXITING THE PROGRAM MODE When all the desired changes in programming have been made, it is time to exit the program mode. Pr
GE Security g LOADING FACTORY DEFAULTS To load the factory defaults, enter the program mode using the procedure on page 24, then type [9]-[
GE Security g PROGRAMMING EXAMPLE (Feature selection data) Location 23, segment 1 1 = Quick arm 2 = Re-exit 3 = Auto bypass 4 = Silent k
GE Security g CONTENTS CONTENTS...
GE Security g Programming the NX-6 control panel via LCD keypad ENTERING THE PROGRAM MODE To enter the program mode, press [*]-[8]. The LC
GE Security g CHARACTER DATA: Character data is used to enter LCD text when programming (see [*]-[9]-[2] feature for custom messages). Cust
GE Security g ALPHANUMERIC CHARACTER TABEL 1 A 20 T 39 ä 58 n 77 # 2 B 21 U 40 ä 59 o 78 $ 3 C 22 V 41 b 60 ô 79 & 4
GE Security g IMPORTANT REMARKS Tamper memorization If location 37 segment 6 option 8 is set, tamper alarm indications (zone tampers an
GE Security g CONTROL PANEL PROGRAMMING LOCATIONS ) For most routine installations, the “Quick Start” option will allow for enabling a maj
GE Security g Segment 2- Phone N° 1 backup control: Programming a “0” in segment 2 of this location will cause the NX-6 to make the designa
GE Security g Reporting events to phone number 1 Phone N°1 has two programming locations that are used to select the events which are repor
GE Security g LOCATION 5 - PARTITIONS REPORTED TO PHONE N° 1 (1 segment, feature selection data) Location 5 is used when the events to be r
GE Security g LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 2 (2 segments, numerical data) Segment 1, dial attempts: segment 1 of
GE Security g Segment 2 1 = Zone and box tamper 2 = Auxiliary power overcurrent, and restore 3 = Wireless sensor missing and restor
GE Security g PROGRAMMING PARTITION PARAMETERS ...
GE Security g LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 3 (2 segments, numerical data) Segment 1, Dial Attempts: Segment 1 o
GE Security g LOCATION 16 - EVENTS REPORTED TO PHONE N° 3 (2 segments, feature selection data) Segment 1 1 = Alarms 2 = Opening and cl
GE Security g Special formats LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (see locations 2, 8, and 14) Segment 1 1 = On for 1800hz transmit;
GE Security g Download parameters ) LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight-digit ac
GE Security g Feature and report selections (for partition 1) ) LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feat
GE Security g Segment 5 1 = Reserved 2 = Reserved 3 = Reserved 4 = Reserved 5 = Reserved 6 = Reserved 7 = Reserved 8 = Reserved
GE Security g Zone configurations and partition selection DEFAULT ZONE CONFIGURATIONS Zones can be programmed to be one of thirty different
GE Security g 12 2 INTERIOR FOLLOWER WITH “CROSS ZONE” ENABLED This zone will be instant when the system is armed and no entry or exit de
GE Security g 24 2 INSTANT ZONE WITH CHIME ENABLED A trip will create an alarm when the system is armed. When the control panel is disarme
GE Security g ) LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data) Location 25 contains the configuration group (zone
GE Security g GENERAL INFORMATION The NX-6-EUR (from now on called NX-6) NetworX from Caddx represents a new approach to the design of se
GE Security g General options LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data) Location 37 is used to enable
GE Security g Segment 5 1 = On: enable lost clock service light 2 = On: enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 =
GE Security g LOCATION 40 - SYSTEM TIMERS (14 segments, numerical data) Location 40 contains the duration of various system timing function
GE Security g LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection data) The “Go To Program Code”
GE Security g Programming the outputs LOCATION 45 - AUXILIARY OUTPUT 1-4 PARTITION SELECTION (4 segments, feature selection data) Location
GE Security g LOCATION 47 - AUXILIARY OUTPUT 1, EVENT AND TIME (2 segments, numerical data) Segment 1 Use the chart below to select the e
GE Security g AUXILIARY OUTPUT EVENT SELECTION DATA EVENT DATA EVENT 09 Burglary alarm 289 Expander trouble 19 Fire alarm 29 Dynam
GE Security g Setup for auto-test, auto-arm and opening/closing times LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data) Segment 1
GE Security g LOCATION 54 - DAYS OF THE WEEK “ARM ONLY AFTER CLOSE WINDOW” CODES FUNCTION IN PARTITIONS 1 AND 2 (2 Segments, feature selec
GE Security g Communicator codes for slow speed formats only LOCATIONS 56-83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER, OR WHEN USING
GE Security g FEATURE DEFINITIONS Abort If this option is enabled, the NX-6 will wait the programmed number of seconds (0-255) in locati
GE Security g LOCATION 58 - TAMPER COMMUNICATOR CODE, SLOW SPEED FORMATS (8 segments, numerical data) Location 58 contains the event code
GE Security g LOCATION 60 - SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data) Location 60 contai
GE Security g LOCATION 63 - KEYPAD AUXILIARY 1 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data) Location 63 contains
GE Security g LOCATION 68 - AC FAIL / AC FAIL RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data) Location 6
GE Security g LOCATION 73 - Reserved LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS
GE Security g LOCATION 78 - CLOSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data) Location 78 contains the ten
GE Security g LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4 segments, numerical data) Location 82 contains the t
GE Security g Programming partition parameters LOCATIONS 88-109 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES AND/OR FEATURES FOR EACH PARTIT
GE Security g Programming zone configuration groups LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE CONFIGURATIONS AS LISTED IN THE TABLE ON
GE Security g Segment 4 1 = On: enables zone activity monitor 2 = On: enables end of line resistor defeat on non-fire/non-keyswitch zones
GE Security g Auxiliary power overcurrent The NX-6 will light up the “Service” LED on the keypad whenever too much current is being drawn
GE Security g LOCATION 117 - CONFIGURATION GROUP 4 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration G
GE Security g LOCATION 124 - CONFIGURATION GROUP 8 ALARM EVENT CODE (1 segment, numerical data) Location 124 contains the event code that i
GE Security g LOCATION 131 - CONFIGURATION GROUP 11 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration G
GE Security g LOCATION 138 - CONFIGURATION GROUP 15 ALARM EVENT CODE (1 segment, numerical data) Location 138 contains the event code that
GE Security g LOCATION 145 - CONFIGURATION GROUP 18 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration
GE Security g LOCATION 152 - CONFIGURATION GROUP 22 ALARM EVENT CODE (1 segment, numerical data) Location 152 contains the event code that
GE Security g LOCATION 159 - CONFIGURATION GROUP 25 CHARACTERISTIC SELECT (5 segments, feature selection data) Use the “Configuration
GE Security g LOCATION 166 - CONFIGURATION GROUP 29 ALARM EVENT CODE (1 segment, numerical data) Location 166 contains the event code that
GE Security g LOCATIONS 207-211 - RESERVED LOCATION 212 – PROGRAMMING THE LCD KEYPAD ADDRESS (1 segment, numerical data) When using the X
GE Security g NX-6 PROGRAMMING WORKSHEETS (Factory defaults for NX-6-EUR (BEL/POL) are in bold italic text) LOC PG DESCRIPTION DEFAUL
GE Security g Configuration groups The NX-6 has 30 configuration groups that determine how each zone will function and report. The default
GE Security g 12 38 PHONE 3 14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14-14 13 38 PHONE 3, ACCOUNT CODE 10 – 10 – 10 – 10
GE Security g PARTITION 1, FEATURE SELECTION Segment 1 Segment 2 Segment 3 1 Quick Arm 1 LED extinguish enable 1 Open/Close 2 R
GE Security g SIREN AND SYSTEM SUPERVISION Segment 1 (Circle Numbers To Program) 1 Siren sounds for telephone line cut while armed 2 S
GE Security g 38 50 SWINGER COUNTDOWN COUNT 0 KEYPAD SOUNDER CONTROL Segment 1 (Circle Numbers To Program) 1 Keypad sounds for Teleph
GE Security g 42 51 GO TO PROGRAM CODE 9-7-1-3-0-0 GO TO PROGRAM CODE PARTITION AND AUTHORIZATION Segment 1 (Circle Numbers To Prog
GE Security g OPENING TIME Segment 1 Program the hour of the opening time 8 52 56 Segment 2 Program the minutes after the hour of the
GE Security g ALARM AND RESTORE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY Segment 1 Zone 1-15 Alarm code 0 Segment 2 Zone 16 Alarm co
GE Security g 81 64 START PROGRAMMING / END PROGRAMMING 0-0-0-0 82 65 RESERVED / END DOWNLOAD 0-0-0-0 83 65 CANCEL COMMUNICATOR CODE
GE Security g 110 67 CONFIGURATION GROUP 1 ALARM CODE 4 CONFIGURATION GROUP 1 CHARACTERISTIC SELECT Segment 1 (Circle Numbers To
GE Security g 136 71 CONFIGURATION GROUP 14 ALARM EVENT CODE 7 137 71 CONFIGURATION GROUP 14 CHARACTERISTIC SELECT 5-1256-25678 1
GE Security g Exit error If this option is enabled, the NX-6 will send an “Exit Error Report” when an entry/exit zone is faulted, at the i
GE Security g BOARD INSTALLATION Diagram 1: Inside the can, several 2-holed insertion points have been constructed. This allows for ei
GE Security g NX-6 WIRING DIAGRAM 1AUX 4(SMOKE +)3COM2COM4COMPOSCOMDATA5312AUX +ZONES6COMBELL +BELL -ACACEARTHKEYPADAux. Outs 1 - 3 Curre
GE Security g TERMINAL DESCRIPTION TERMINAL DESCRIPTION R1 House Telephone Ring. R Telephone Ring. T Telephone Tip. T1 House Tele
GE Security g TECHNICAL SPECIFICATIONS Technical specifications NX-6 - Nominal 14.05 Vac - 18.15 Vac 70 mA Auxiliary Power 13.85 Vdc/1.5
GE Security g Technical specifications NX-1308, NX-1316, NX-1324 Operating power - Nominal 12 Vdc - Minimum/maximum 9 Vdc - 1
GE Security g APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA The table below lists the event codes sent for the following repo
GE Security g THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER. IF THERE ARE NO PARENTH
GE Security g APPENDIX 2: REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-6 has the ability to report SIA level 1 transmissions to eit
GE Security g The NX-6 can report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a Zone ID. The
GE Security g APPENDIX 3: EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE The tables below list the device numbers that will be reported f
Komentarze do niniejszej Instrukcji