CADDX NX-6 Instrukcja Instalacji Strona 70

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 104
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 69
GE Security
g
LOCATION 117 - CONFIGURATION GROUP 4 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 118 - CONFIGURATION GROUP 5 ALARM EVENT CODE (1 segment, numerical data)
Location 118 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 119 - CONFIGURATION GROUP 5 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 120 - CONFIGURATION GROUP 6 ALARM EVENT CODE (1 segment, numerical data)
Location 120 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 121 - CONFIGURATION GROUP 6 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 122 - CONFIGURATION GROUP 7 ALARM EVENT CODE (1 segment, numerical data)
Location 122 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on page 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 123 - CONFIGURATION GROUP 7 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
NX-6-EUR Installation manual Page 70 23/12/04