GE Security
g
IMPORTANT REMARKS
Tamper memorization
If location 37 segment 6 option 8 is set, tamper alarm indications (zone tampers and box
tampers) can be erased by entering a valid user code.
If location 37 segment 6 option 8 is not set, tamper alarm indications (zone tampers and
box tampers) can only be erased by entering the program mode. In this case, tamper
alarm indications can only be reset by the installer.
Disabling tamper alarms in program mode
Tamper alarms (originating from zones and boxes) will be disabled during program mode.
This allows the installer to service the system without generating unwanted tamper
alarms. Note that the timeout for the program mode is 15 minutes.
Country code
The NX-6 has the ability to set different “country codes”. Each country code has specific
default settings. Before start programming the NX-6, it is important to select the country
code that is required. Once the country code has been selected, it will remain set, even
after an installer reset. When changing the country code during programming, all existing
programming will be cleared to the defaults for that country (see location 213).
Keypad tamper lockout
When this option is enabled (see location 23, segment 1), the NX-6 will disable the
keypad for 60 seconds, and will communicate a tamper signal to the central station if 30
key presses are entered without producing a valid code.
NX-6-EUR Installation manual Page 33 23/12/04