g
LOCATION 68 - AC FAIL / AC FAIL RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS
ONLY (4 segments, numerical data)
Location 68 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
“AC Fail Reporting” is enabled. Segment 1 contains the tens digit of the “AC Fail
Reporting”. Segment 2 contains the ones digit of the “AC Fail Reporting”. Segment 3
contains the tens digit of the “AC Fail Restore”. Segment 4 contains the ones digit of the
“AC Fail Restore”. For a 3+1 format, only the segment 1 resp. segment 3 digit (tens) will
be sent.
LOCATION 69 - LOW BATTERY / LOW BATTERY RESTORE COMMUNICATOR CODES, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 69 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
“Low Battery Reporting” is enabled. Segment 1 contains the tens digit of the “Low Battery
Reporting”. Segment 2 contains the ones digit of the “Low Battery Reporting”. Segment 3
contains the tens digit of the “Low Battery Restore”. Segment 4 contains the ones digit of
the “Low Battery Restore”. For a 3+1 format, only the segment 1 digit resp. segment 3
digit (tens) will be sent.
LOCATION 70 - AUX POWER OVERCURRENT/ AUX POWER OVERCURRENT RESTORE
COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 70 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
“Aux Power Overcurrent Reporting” is enabled. Segment 1 contains the tens digit of the
“Aux Power Overcurrent Reporting”. Segment 2 contains the ones digit of the “Aux Power
Overcurrent Reporting”. Segment 3 contains the tens digit of the “Aux Power Overcurrent
Restore”. Segment 4 contains the ones digit of the “Aux Power Overcurrent Restore”. For
a 3+1 format, only the segment 1 resp. segment 3 digit (tens) will be sent.
LOCATION 71 - BELL TAMPER AND BELL TAMPER RESTORE COMMUNICATOR CODES, SLOW
SPEED FORMATS ONLY (4 segments, numerical data)
Location 71 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
siren supervision reporting is enabled. Segment 1 contains the tens digit of the “Bell
Tamper Reporting”. Segment 2 contains the ones digit of the “Bell Tamper Reporting”.
Segment 3 contains the tens digit of the “Bell Tamper Restore”. Segment 4 contains the
ones digit of the “Bell Tamper Restore”. For a 3+1 format, only the segment 1 resp.
segment 3 digit (tens) will be sent.
LOCATION 72 - TELEPHONE LINE CUT RESTORE COMMUNICATOR CODES, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 72 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
“Telephone Line Cut Restore Reporting” is enabled. Segment 1 and segment 2 are
reserved. Segment 3 contains the tens digit of the “Telephone Line Cut Restore”.
Segment 4 contains the ones digit of the “Telephone Line Cut Restore”.
For a 3+1 format, only the segment 3 digit (tens) will be sent.