LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (4
segments, numerical data)
Location 82 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if
“End Downloading Reporting” is enabled. Segment 1 and 2 are reserved. Segment 3
contains the tens digit of the “End Download Reporting”. Segment 4 contains the ones
digit of the “End Download Reporting”. Note: A start download report will be sent to the
internal event log.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
LOCATION 83 - CANCEL COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (1 segments,
numerical data)
Location 83 contains the tens digit for a 4+2 and 3+1format that will be sent if “Cancel
Reporting” is enabled. Segment 1 contains the tens digit for the “Cancel Communicator
Reporting”. As ones digit, the user number (1-F) of the user who cancelled, will be sent. If
you need to report Cancels with a unique code per user, Contact ID or SIA format must
be used.
LOCATIONS 84-87 - RESERVED