INSTANT ZONE WITH CHIME ENABLED
A trip will create an alarm when the system is armed. When the control panel is
disarmed and the chime mode has been set, this zone will act as a chime zone.
25 2
FOLLOWER ZONE WITH CHIME ACTIVATED
This zone will be instant when the system is armed and no entry or exit delays are being
timed. It is delayed during entry and exit delay times. This zone will not bypass
automatically, even if enabled in segment 1 of location 23. When the control panel is
disarmed and the chime mode has been set, this zone will act as a chime zone.
26 2
24 HOUR, AUDIBLE, SUPERVISED, LOCAL
Creates an instant audible alarm, regardless of the arming state of the control panel. It
will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). This
zonetype will NOT be reported.
27 2
INSTANT ZONE FORCE ARMABLE
This zone creates an instant alarm whenever the system is armed. This zone is force
armable (see feature definitions, pages 5-11).
28 2
INSTANT ZONE ACTIVITY MONITOR ENABLED
This zone creates an instant alarm whenever the system is armed. It will send a report if
the zone activity time is reached without a change of state (see location 40, segment 11
and locations 110-169).
29
INSTANT ZONE WITH END OF LINE RESISTOR DEFEAT
This zone creates an instant alarm whenever the system is armed. When the loop is
closed, the zone is ready. Opening of the loop means a faulted zone (see locations 110-
169).
30 2
24 HOUR, MEDICAL, AUDIBLE, SUPERVISED
Creates an instant audible alarm, regardless of the arming state of the control panel. It
will display on the keypad (e.g. flashing zone LED’s, and changed READY LED). A
medical report will be sent to the CMS.
Note: all zone configurations are programmed for double end of line resistor
configuration, except for DAY ZONE, FIRE, 24H AUDIBLE SUPERVISED and END
OF LINE RESISTOR DEFEAT.