GE Security
g
38 50 SWINGER COUNTDOWN COUNT 0
KEYPAD SOUNDER CONTROL
Segment 1 (Circle Numbers To Program)
1 Keypad sounds for Telephone Line Cut when in the Armed state
2 Keypad sounds for Telephone Line Cut when in the Disarmed state
3 Keypad sounds upon AC Power Failure
4 Keypad sounds upon Low Battery Detection
5 Keypad sounds during Cross Zone Trip Time
6 Keypad sounds for Tamper Alarm
7 Reserved
39
50
8 Keypad sounds for Expander Trouble
SYSTEM TIMERS
Segment 1 Dynamic Battery Test duration (0-255 minutes) 0
Segment 2 AC Failure report delay (0-255 minutes) 60
Segment 3 Power Up Delay (0-60 seconds) 0
Segment 4 Siren Time (1-255 minutes) 3
Segment 5 Telephone Line Cut delay (0-255 seconds) 0
Segment 6 Cross Zone Time (0-255 minutes) 5
Segment 7 Chime Time in 50 mS increments (0-255) 5
Segment 8 Dialer delay (0-255 seconds) 0
Segment 9 Fire Alarm Verification Time (120-255 seconds) 0
Segment 10 Listen-In Time (0-255 seconds) 0
Segment 11 Zone monitor timer hours/days (0-255) 0
Segment 12 Auto arming warning timer (1-255 minutes) 1
Segment 13 Auto arming retry timer (1-255 minutes) 45
40 51
Segment 14 Reserved 0
USER CODE REQUIREMENTS
Segment 1 (Circle Numbers To Program)
1 Enables six digit code option. All arm/disarm/Go to program codes require six digits
2 Requires valid user code entry so that [*]-[9]-[8] and [*]-[9]-[9] functions can work
3 Reserved
4 Reserved
5 On: keypad shutdown mode
6 On: user authorization to enter program mode
7 On: codes 16 and 17 are guard codes
41
51
8 Reserved
NX-6-EUR Installation manual Page 83 23/12/04