1 = On: enables zone activity monitor
2 =
On: enables end of line resistor defeat on non-fire/non-keyswitch
zones
3 =
On : enables zone to act as request to exit input / disables for
alarm activation
4 = On : enables zone to act as access entry point (Door Shunt) ()
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Segment 5
1-8 Reserved
Note :
Refer to NX-1701E card reader installer manual. Do not enable this segment
unless configured with Access Control.
LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 113 - CONFIGURATION GROUP 2 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 114 - CONFIGURATION GROUP 3 ALARM EVENT CODE (1 segment, numerical data)
Location 114 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may
also contain the alarm report code for the Robofon format (value 00-99).
LOCATION 115 - CONFIGURATION GROUP 3 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 116 - CONFIGURATION GROUP 4 ALARM EVENT CODE (1 segment, numerical data)
Location 116 contains the event code that is sent for a Contact ID or SIA report. The
desired event code should be chosen from the list on pages 121-122. The zone ID will be
the zone that is in alarm. This location is not used for slow speed formats (like 4+2 and
3+1). This location may also contain the alarm report code for the Robofon format (value
00-99).